CAD模型選擇
{kingspan_insulation/tek.prj},{NB=Kingspan TEK Building System - Roof-Roof(30020001220UKEN2)142},{CT=142},{BMTCK=15},{TC=0.024},{OSBFT=0.13},{STTC=0.13},{VR=49},{IE=0.9},{ECAR=MIN},{RECCON=MIN},{PN=Kingspan TEK Building System - Roof},{T=Roof},{BMT=OSB},{BMP=Both},{BTR=1.0% Timber},{APP=Building System},{TR=4.859},{RTF=D-s2,d0 - 15mm OSB facing / E - PUR Core},{BBA=02/S029},{LODLEVEL=300},{L=2000},{CW=1220},{AA=2},{CON=UK},{LNG=EN}
請根據技術需求選擇所需產品. 可選屬性在表格中高亮顯示. 選擇可以通過點擊表格或數值來重置.
添加用於比較
Kingspan TEK Building System - Roof 142
HELP_VARIABLE
Product
Kingspan TEK® Building System - Roof
Kingspan TEK® Building System - Roof
Core Thickness (CT)
142
142
mm
LOD Level
300
200
300
200
Length
mm
Enter value for L
Length
mm
cm
inch
ft
確定
Width
mm
Enter value for CW
Width
mm
cm
inch
ft
確定
Bonded material type
OSB
Bonded material thickness
15
Bonded material position
Both
Bridge Thermal Resistance
1.0% Timber
1.0% Timber
Thermal Resistance
4.859
4.859
W/mK
Insulation core thermal conductivity λD
0.024
W/m K
OSB Face thermal conductivity λD
0.13
W/(m.K)
Solid timber thermal conductivity λD
0.13
W/(m.K)
Reaction to fire
D-s2,d0 - 15mm OSB facing / E - PUR Core
BBA Certification
02/S029
Disclaimer
All U-value calculations created utilising Kingspan TEK must take account of thermal bridging. Please contact the Kingspan Insulation Technical Department for more details. Kingspan TEK Building System - can be used to create buildings up to 4 storeys. However, please note there are potential restrictions placed upon this product which vary dependant on building type, height, construction and location. For guidance regarding the routes to compliance for meeting the fire safety requirements of the Building Regulations / Standards, refer to the relevant links to Government websites at www.kingspantek.co.uk/fireregulations. Kingspan TEK Cladding Panel - there are potential restrictions placed upon this product which vary dependant on building type, height, construction and location. For guidance regarding the routes to compliance for meeting the fire safety requirements of the Building Regulations / Standards, refer to the relevant Technical Bulletins and links to Government websites at www.kingspantek.co.uk/fireregulations.
Manufacturing Facility
This product is manufactured at Kingspan's Selby, North Yorkshire manufacturing facility.
Product Page
https://www.kingspan.com/gb/en/products/structural-insulated-panels/tek-building-system/
Previews
3D
尺寸
2D
下載CAD模型
生成CAD模型
生成PDF資料表
分類
CNS
Geometrical Properties:
LOG Destination:
LOG:
300
Object Properties:
Type Code:
Kingspan TEK Building System - Roof 142
BIM增强:
ETIM 7.0
Insulation mat/basin:
Revit
(Metric) Generic Model wall based:
OmniClass 2006
23-20 50 24 Thermal Insulation:
CIBSE PDT
Insulation:
OmniClass
23-13 35 21 19 15 - Structural Insulated Panels:
Additional Information
相應設備
Similar parts
No related equipment available